Welcome to the GMC Instruments China English website.
METRALINE PRO-TYP EM II

METRALINE PRO-TYP EM II

The various charging cables are simulated by connecting different resistances between PP and PE with the help of a rotary switch. The following values are possible in accordance with IEC 61851:

☆ No cable – 0 Ω

☆ 13 A cable – 1.5 kΩ

☆ 20 A cable – 680 Ω

☆ 32 A cable – 220 Ω

☆ 63 A cable – 100 Ω

Delivery

1 METRALINE PRO-TYP EM II test adapter
1 set of operating instructions

Phone Number:+86 13817443004

Product Details/ Content details

METRALINE PRO-TYP EM II

Item number: Z525G

Test Adapter for Electric Charging Points (single/3-phase, type 2) for PROFITEST incl. schuko socket

Single and 3-phase test adapter with type 2 plug for testing the effectiveness of protective measures at electric charging points with the Profitest Master, simulation of fictitiously connected electric vehicles and current-carrying capacity per IEC 61851-1. Extended CP test pin for testing charging points with permanently attached charging cable.

Test Adapter for Electric Charging Points (single/3-phase, type 2) for PROFITEST incl. schuko socket

☆ Vehicle simulation (CP)
Vehicle states A through E are selected with a rotary switch.

☆ Cable simulation (PP)
The various codings for charging cables with 13, 20, 32 and 63 A, as well as “no cable connected”, can be simulated with the help of a rotary switch.

☆ Fault simulation
Simulation of a short-circuit between CP and PE by means of a rotary switch

☆ Indication of phase voltages via LEDs
Depending on the charging station, either one or three phases can be active.

☆ Testing of electric charging stations with permanently attached charging cable by means of an extended CP test pin

Regarding vehicle simulation (CP)
States A, B, C and E can be simulated in accordance with IEC 61851. The various vehicle states are selected by means of a rotary switch.

☆ State A – no vehicle connected

☆ State B – vehicle connected but not ready for charging

☆ State C – vehicle connected and ready for charging, venting of the charging area not required

☆ State E – error: Short circuit between CP and PE via internal diode

Regarding cable simulation (PP)
The various codings for charging cables with 13, 20, 32 and 63 A can be simulated. It’s also possible to simulate the “no cable” state.

The various charging cables are simulated by connecting different resistances between PP and PE with the help of a rotary switch. The following values are possible in accordance with IEC 61851:

☆ No cable – 0 Ω

☆ 13 A cable – 1.5 kΩ

☆ 20 A cable – 680 Ω

☆ 32 A cable – 220 Ω

☆ 63 A cable – 100 Ω

Delivery

1 METRALINE PRO-TYP EM II test adapter
1 set of operating instructions

no cache
Processed in 0.406636 Second.